SINCOLD, THE TRUE FACE OF TECHNOLOGY. We do not manufacture blast chillers to seduce the eye, we build them to achieve results. It is not equipment for anyone. It is for those who need to regain their trust in technology. Thanks to exclusive, easy-to-use technology, Nuovair's blast chillers can increase performance by up to 20%: in practice, this gives you up to one extra chilling cycle every day. The large choice of roll-in or reach-in systems meets every production requirement and ensures higher standards for the food, which remains as fresh as if it had just.
Consistent Results. Now available at the tip of your finger.
- Two user-friendly modes: Auto or Manual Menu mode not only improves food safety over regular refrigeration, but it also ensures high-volume production accuracy.
- By inserting the ProbeChillTM, the Auto Menu function launches automatically, using the factory default or manager-specified settings.
- The on-board printer enables you to meet HACCP documentation requirements as your food progresses through the Danger Zone.
Two Modes. To use the blast chiller, the operator simply selects one of two modes on the Epicon visual interface touch screen—or inserts our ProbeChill—to begin the chilling process. This ease of use not only improves food safety over regular refrigeration, but it also ensures high-volume production accuracy. So, when preparing large quantities, you can achieve consistent, repeatable results.
Auto Menu can be launched in two ways. The user can insert the ProbeChill, and the blast chiller will launch the Auto Menu function, using the factory default standard temperature setting of 37˚F. The chiller will beep when the food has reached 37˚F. If the operator would rather chill by set time, pressing “EZ TIME” once the ProbeChill is inserted will ensure the food is chilled within the factory default time of 90 minutes. For simple menu recall or for items where using the ProbeChill could affect final presentation, select Auto Menu and pull up a saved product by name. Press “Start” and the chiller does the rest. It really is that simple.
With the Manual Menu, you have complete control over the blast chiller operation. The Epicon visual interface keeps things simple, however, with a series of guided steps. To start with, the chef selects the operating program “by temp,” “by time” or “by preset recipe.” Next, the chef enters the product name—lasagna, for example—as well as his or her username. In this example, the chef selected “by temp.” Using the down arrow, the chef enters the desired end temperature (in this case, 32˚F). Next, the chef can select one of four “chill methods.” The blast chiller will use “standard” as the default chill setting, unless the user touches a chill-setting icon after entering the time. Finally, the chef presses “Start.” As with Auto Menu, key batch data will be displayed on the run screen. So, at any time, anyone can check start and finish temperature, chill time, product name selected and finally, the username assigned to the batch.
Easy networking. The on-board printer enables you to meet HACCP documentation requirements as your food progresses through the Danger Zone. With the added option of our label printer, you can also create adhesive labels to apply to your products’ containers. With clear chill data for your staff and the health inspector, say so long to hard-to-read handwritten labels or operator error. Traulsen makes reporting automatic. But it takes more than that to be HACCP compliant. You also have to be able to determine which employee handled the product each step of the way. That’s why Traulsen’s Epicon visual interface lets you assign individual operator ID names or numbers for later identification.
Four different settings give you complete flexibility. When using Manual Menu mode, the saved chill method is the automatic default chill setting. If you tell your prep cook you’re in a time crunch, however, he or she can easily select “Speed” from the chill-method screen, cutting chill time by approximately 10 percent.
1. Standard, for basic operation
2. Speed, reduces chill time by approximately 10% for high-volume operations
3. Delicate, retains moisture and food quality during chill cycle
4. Energy, uses approximately 10% less energy than standard per cycle
Our blast chillers are also better for the environment because they’re built to last, so the product life cycle is significantly longer. Our heavy-duty construction is designed to hold up in your demanding environment. The stamped metal will not crack or break. Finally, our one-piece sides and lack of exterior fasteners prevent soil buildup and improve overall cabinet strength, making sure the blast chiller stands up to years of heavy use.
Chilling in as little time as possible is critical. That’s why our cyclonic airflow system creates a horizontally moving curtain of air that extends from the top of the chiller to the bottom. Like other TempAssure airflow systems, the air is circulated to maintain balanced product temperatures. These two innovations ensure that food can be chilled in approximately 90 minutes. You can also adjust the product holding temperatures and product chill endpoint to preserve the individual characteristics of your foods. For salads and fruits, this means that the constant cool airflow ensures food remains consistently fresh.
TBC1H-TBC2H
Roll In & Roll Through Blast Chiller
SPEC SHEET
TBC Series
Blast Chiller Remote Information
SPEC SHEET
Quick Chiller Model, 48″ Length
Quick Chiller
SPEC SHEET
One, Two and Three Door Models, 34″ Deep
Chiller
SPEC SHEET
Hover over image to zoom
More Views
Quickfind: MXT14.40
Details
Special Functions
Constructed in stainless steel AISI 304 18/10, interior sides with mirror finishing, space under the evaporator to allow an easy cleaning, core probe as standard, self-closing door equipped with a silicone gasket resistant to low temperatures, magnetic and heated door frame, stainless steel feet adjustable in height, technical room of evaporator and condenser can be easily inspected through a compass opening, curved bottom and drain hole for condensation and water run out.
Write Your Own Review
Only registered users can write reviews. Please, log in or register
Sincold Blast Chiller Manual Parts
Sincold EVOX FT Blast Chiller - Freezer Compact- SQX5FT.12C
Out of stock
Sincold EVOX FT Blast Chiller - Freezer Compact - SQX5FT.12CW
Out of stock
Sincold EVOX FT Blast Chiller - Freezer Built in Unit - SQX5FT.12ST
Out of stock
Sincold Blast Chiller Manual Free
Drop on Griddle Plate, 227002
Out of stock
Evolution Series Mobile Castor Kit, 228807
Out of stock
Adande Compact Solid Worktop Counter Unit VCC1
Out of stock
Adande Refrigeration Under Counter Double Drawer Unit VCS2
Out of stock
Amika AM91XL Pass Through Hood Dishwasher - optional drain pump
Out of stock
Valentine EVO 2525 Twin Tank Twin Basket Freestanding Electric Fryer
Out of stock
SP100 floor stand (only sold with purchase of mixer)
Out of stock
Metcalfe Potato Peeler (10lb/4.5kg), EP10, Painted finish
Out of stock
Roband High Speed Smooth Plate Grill/Griddle - GSA815S
Out of stock